Finden Sie schnell ethernet lan kabel für Ihr Unternehmen: 160 Ergebnisse

RE-Y(St)Y-fl & RE-Yw(St)Yw-fl

RE-Y(St)Y-fl & RE-Yw(St)Yw-fl

INSTRUMENTATION CABLES, EN 50288-7SINGLE & MULTI-TRIPLE, PVC INSULATED, COLLECTIVE SCREENED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. For application of 105oC heat resistant, RE-Yw(St)Yw cables are suitable. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (Y): PVC compound, 70 oC grade; EN 50290-2-21 Insulation (Yw): PVC compound, 105 oC grade; EN 50290-2-21 Core identification: Black / Blue / Red cores are numbered, (1-1-1, 2-2-2,…), Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Triple: Three conductors twisted to a triple Lay-up: Triples laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath (Y): PVC compound, 70 oC grade; EN 50290-2-22 Outer sheath (Yw): PVC compound, 105 oC grade; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Min. bending radius: 7,5 x D Flame retardance test: IEC 60332-1 & EN 60332-1 Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 100 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 105 oC, ınstallation : - 5 oC ~ + 50 oC
Patchkabel RJ45 6kV Flex500 Outdoor AWG 24

Patchkabel RJ45 6kV Flex500 Outdoor AWG 24

‧ RJ45 Patchkabel für Industrie und Außenanwendungen ‧ geschirmtes Cat.5e, Class EA RJ45 Patchkabel ‧ Einhaltung des Klasse EA Channel-Link nach ISO/IEC 11801-1, DIN EN 50173-1 ‧ getestet: Channel-Link bis 500 MHz ‧ für 10 GBit/s Ethernet (IEEE 802.3an) bis 40m geeignet ‧ besonders geeignet für ungeschirmte und geschirmte Class EA Systeme ‧ Robustes und abriebfestes Kabel für die Industrieanwendung, wie im Maschinen- und Anlagenbau. Ebenfalls geeignet für die Verlegung im Freien ‧ Einhaltung der VDE-AR-N 4100:2019-04 (6KV Stoßspannungsprüfung nach DIN EN 60664-1) bei Verlegung in Zählerplatz und Elektroverteilern ‧ Kabeltyp: S/UTP 4x2xAWG24/7 ‧ Kabelmantel LSHF (FRNC) PUR; schwarz ‧ Das Kabel ist für wiederholte bewegte Anwendung (Schleppkette) konstruiert. Getestet mit einem Biegeradius von 100mm und einer Beschleunigung von 4m/s² wurden 3 Mio. Zyklen bei Raumtemperatur erreicht. ‧ zwei geschirmte RJ45-Stecker, Beschaltung 1 - 1 ‧ UV; Öl beständig ‧ Remote Powering (PoE, PoE plus und UPoE) für IoT; M2M, IoT; HDBaseT; Industrie 4.0; Multimedia; Breitband-Video geeignet ‧ Knickschutztülle umspritzt ‧ deutlich längere Haltbarkeit als Standard-Patchkabel ‧ sehr kurze Knickschutztülle
Patchkabel RJ45 Cat.6 Ultraflex500 VoIP AWG 26

Patchkabel RJ45 Cat.6 Ultraflex500 VoIP AWG 26

‧ optimale Lösung bei Platzmangel ‧ besonders geeignet für ungeschirmte und geschirmte Class EA Systeme ‧ vollgeschirmtes Cat.6 Patchkabel AWG 26/7 ‧ zwei geschirmte RJ45-Stecker, Beschaltung 1 - 1 ‧ Kabeltyp: S/FTP 4x2xAWG 26/7 PIMF ‧ Kabelmantel PUR ‧ sehr kurze Knickschutztülle ‧ besonders geeignet für VoIP Endgeräte ‧ Biegeradius von bis zu 10 mm möglich ‧ deutlich längere Haltbarkeit als Standard-Patchkabel ‧ problemlos bis zu 8500 Bewegungszyklen unter Belastung
Patchkabel RJ45 Cat.6A AWG 26

Patchkabel RJ45 Cat.6A AWG 26

‧ GHMT PVP zertifiziertes, vollgeschirmtes RJ45 Patchkabel Cat.6A AWG 26/7 ‧ Ideal für die Integration oder Verbindung von Netzwerkkomponenten und die sichere Übertragung von Sprach-, Daten-, Audio-/Video - und/oder PoE-Signalen in bandbreitenintensiven Netzwerken bis 10 GBit. ‧ besonders geeignet für ungeschirmte und geschirmte Class EA Systeme ‧ zwei geschirmte RJ45-Stecker, Beschaltung 1 - 1 ‧ LaBS-frei und halogenfrei ‧ geeignet für 10 GBit Ethernet (IEEE 802.3an), Remote Powering (PoE, PoE plus und UPoE) und HDBaseT ‧ Knickschutztülle gespritzt mit integriertem Rasthebelschutz ‧ gleiche Breite für Knickschutztülle und RJ45 Stecker ‧ Varianten, Farbe: schwarz, weiß, grau, rot, blau, gelb, grün, orange-schwarz, violett-schwarz, lila-schwarz ‧ Varianten, Verpackungseinheit: 1 Stück in Polybeutel (130845xxyy-E) oder 10 Stück in Polybeutel (130845xxyy-Z) ‧ alle verfügbaren Varianten können über den Konfigurator erstellt werden
Patchkabel RJ45 Cat.6A AWG 27 cULus

Patchkabel RJ45 Cat.6A AWG 27 cULus

‧ besonders geeignet für ungeschirmte und geschirmte Class EA Systeme ‧ cULus gelistet / DUXR.E178484 ‧ vollgeschirmtes Cat.6A Patchkabel AWG 27/7 ‧ zwei geschirmte RJ45-Stecker, Beschaltung 1 - 1 ‧ Kabeltyp: S/FTP 4x2xAWG 27/7 PIMF ‧ Kabelmantel LSHF(LSOH), halogenfrei ‧ Cat.6A Komponentenprüfung nach ISO/IEC 11801-1 und IEC 61935-2 ‧ Class EA Link bis 500 MHz nach ISO/IEC 11801-1, DIN EN 50173-1 ‧ für 10GBit Ethernet (IEEE 802.3an), Remote Powering (PoE, PoE plus, UPoE) und HDBaseT geeignet ‧ Knickschutztülle gespritzt mit integriertem Rasthebelschutz ‧ Farben können produktionsbedingt geringfügig abweichen
Hochflexible Kabel & Leitungen

Hochflexible Kabel & Leitungen

Flexible Kabel & Leitungen für Schleppketten werden gezielt für Einsatzbereiche mit sehr hohen Wechselbiege-Beanspruchungen produziert, wie zum Beispiel Fertigungsstraßen, Hochregallager oder Verpacku Hochflexible Kabel von SAB zeichnen sich unter anderem durch eine extrem hohe Lebenserwartung bei gleichzeitig kleinstmöglichem Biegeradius aus. Ein Spitzenprodukt unserer SABFlex Reihe ist die Type S 980 P, die u.a. durch die UL, CSA, VDE Zulassung den hohen Qualitätsstandard unserer Schleppkettenleitungen demonstriert. Schleppkettenleitungen erlauben einen Dauereinsatz im Mehrschichtbetrieb mit hohen Verfahrgeschwindigkeiten und extrem hohen Biege-Beanspruchungen. So können Sie gezielt unsere fortschrittliche Leitungstechnologie nutzen, um die Wirtschaftlichkeit Ihrer Maschinen und Anlagen zu verbessern und Ihrem Wettbewerb immer einen Schritt voraus zu sein. Abmessung: nach Kundenwunsch Sonderfertigung: ab 300 m möglich
USB Kabel, flexible

USB Kabel, flexible

Flexible USB 2.0 und USB 3.0 Kabel & Leitungen für die Hochfrequenz-Datenübertragung im industriellen Umfeld.
RE-2Y(St)HSWAH & RE-2X(St)HSWAH-MP

RE-2Y(St)HSWAH & RE-2X(St)HSWAH-MP

HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)HSWAH,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHEDRE-2X(St)HSWAH,SINGLE & MULTI-PAIR, XLPE INSULATED, COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHED Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / White cores numbered 1-1, 2-2,…, Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: HFFR compound, EN 50290-2-27 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath: HFFR compound, EN 50290-2-27 Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2
RE-2Y(St)HSWAH&RE-2X(St)HSWAH-MP

RE-2Y(St)HSWAH&RE-2X(St)HSWAH-MP

HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)HSWAH,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTİVE SCREENED, ARMOURED, LSZH SHEATHEDRE-2X(St)HSWAH,SINGLE & MULTI-PAIR, XLPE INSULATED, COLLECTİVE SCREENED, ARMOURED, LSZH SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Insulation (2X): XLPE compound, GP8, BS 7655 (RE-2X….) Core identification: According to BS 5308 Part 1 colour coded , Note: Other core configurations manufactured upon request Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: LSZH compound, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: LSZH compound, LST1, BS 7655, LSZH : Low Smoke Zero Halogen Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain annealed copper wire, BS 6360, 0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation (2Y): PE compound, BS 6234 Type03 (RE-2Y….) Standard: Designed acc. to BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range (2Y): operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 40 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 8 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1, IEC 60332-3 & BS EN 50266-2-4 Smoke density test: IEC 61034-2 & BS EN 61034-2 Halogen-free properties test: IEC60754-1/2 & BS EN 50267-2
RE-2Y(St)HSWAH & RE-2X(St)HSWAH MP

RE-2Y(St)HSWAH & RE-2X(St)HSWAH MP

HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)HSWAH,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHEDRE-2X(St)HSWAH,SINGLE & MULTI-PAIR, XLPE INSULATED, COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / Blue cores numbered 1-1, 2-2,…, Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: HFFR compound, EN 50290-2-27 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath: HFFR compound, EN 50290-2-27 Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Standard: TS/DIN EN 50288-7 Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 500V Test voltage: Urms core-core : 2000 V, Urms core-screen : 2000 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2
RE-2Y(St)H&RE-2X(St)H-MP

RE-2Y(St)H&RE-2X(St)H-MP

HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 1RE-2Y(St)H,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTİVE SCREENED, LSZH SHEATHEDRE-2X(St)H,SINGLE & MULTI-PAIR, XLPE INSULATED, COLLECTİVE SCREENED, LSZH SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360, 0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation (2Y): PE compound, BS 6234 Type03 (RE-2Y….) Insulation (2X): XLPE compound, GP8, BS 7655 (RE-2X….) Core identification: According to BS 5308 Part 1 colour coded, *Upon request ; Black / White cores numbered 1-1, 2-2,… Pair: Pairs laid up in layers of optimum pitch Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Outer sheath: LSZH compound, LST1, BS 7655, LSZH : Low Smoke Zero Halogen Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range (2Y): operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 40 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 6 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1, IEC 60332-3 & BS EN 50266-2-4 Smoke density test: IEC 61034-2 & BS EN 61034-2 Halogen-free properties test: IEC60754-1/2 & BS EN 50267-2
RE-2Y(St)H & RE-2X(St)H-MP

RE-2Y(St)H & RE-2X(St)H-MP

HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)H,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHEDRE-2X(St)H,SINGLE & MULTI-PAIR, XLPE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / White cores numbered 1-1, 2-2,…, Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath: HFFR compound, EN 50290-2-27 Capacitance unbalance: (1 kHz) : max. 500 pF/500 m Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Min. bending radius: 7,5 x D Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2 Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4
RE-Y(St)YSWAY-fl & RE-Yw(St)YwSWAYw-fl

RE-Y(St)YSWAY-fl & RE-Yw(St)YwSWAYw-fl

INSTRUMENTATION CABLES, EN 50288-7SINGLE & MULTI-TRIPLE, PVC INSULATED, COLLECTIVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Outer sheath (Y): PVC compound, 105 oC grade; EN 50290-2-22 Outer sheath (Yw): PVC compound, 105 oC grade; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (Y): PVC compound, 70 oC grade; EN 50290-2-21 Insulation (Yw): PVC compound, 105 oC grade; EN 50290-2-21 Core identification: Black / White / Red cores are numbered, (1-1-1, 2-2-2,…), Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Triples laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath (Y): PVC compound, 70 oC grade; EN 50290-2-22 Inner sheath (Yw): PVC compound, 105 oC grade; EN 50290-2-22 Armour: Galvenized round steel wire, EN 10257-1 Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 100 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 190 pF/m, 0,75 mm2 : max. 190 pF/m, 1,0 mm2 : max. 190 pF/m, 1,3 mm2 : max. 200 pF/m, 1,5 mm2 : max. 200 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 105 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame retardance test: IEC 60332-1 & EN 60332-1
Patchkabel RJ45 40G AWG 26

Patchkabel RJ45 40G AWG 26

‧ voll-/paargeschirmtes 40G Patchkabel ‧ Kabeltyp: S/FTP 4x2xAWG 26/7 (PiMF) ‧ Kabelmantel: LSHF (LSOH), halogenfrei ‧ zwei robuste, geschirmte und multiportfähige RJ45-Stecker, Beschaltung 1 - 1 ‧ geschützter Verriegelungshaken ‧ Übertragungstechnische Eigenschaften Cat.8.1 nach ISO/IEC 11801 (bis 2000 MHz) ‧ Einhaltung der Klasse I nach ISO/IEC 11801, DIN EN 50173-1 ‧ 40GBASE-T geeignet für 40 Gbit Ethernet (IEEE 802.3bq) ‧ geeignet für Remote Powering (PoE, PoE plus, UPoE und 4PPoE) und HDBaseT geeignet ‧ Standardvarianten: 0,5 m, 1,0 m, 1,5 m, 2,0 m, 3,0 m, 5,0 m
Patchkabel RJ45 25G AWG 26

Patchkabel RJ45 25G AWG 26

‧ paargeschirmtes 25G Patchkabel AWG 26/7, halogenfrei ‧ von akkreditierten Prüflabor zertifiziert nach DTR-11801-9905 für 25GBASE-T im Channel-Link mit 30 m (50 m in Vorbereitung) ‧ zwei geschirmte RJ45-Stecker, Beschaltung 1 - 1 ‧ Standardlänge: 2 m (keine weiteren Standardlängen für 25GBit möglich) ‧ Class EA geprüft nach ISO/IEC 11801 und DIN EN 50173-1 für 25GBit/s Ethernet (IEEE 802.3bq) und 10 GBit/s Ethernet (IEEE 802.3an) geeignet ‧ Knickschutztülle gespritzt mit integriertem Rasthebelschutz
ETFE-, FEP-, PFA Kabel & Leitungen

ETFE-, FEP-, PFA Kabel & Leitungen

Die Leitungen sind für Anwendungen der Tieftemperaturen bis zu – 90°C sowie Hochtemperaturen bis zu + 260°C einsetzbar. Extrem widrige Umgebungen für Kabel und Leitungen verlangen nach extrem beständigen Werkstoffen. Diese Forderung wird durch unsere Kabel aus ETFE, FEP oder auch PFA erfüllt. Die Leitungen sind für Anwendungen im Bereich der Tieftemperaturen bis zu – 90°C sowie Hochtemperaturen bis zu + 260°C einsetzbar. Darüber hinaus sind unsere ETFE, FEP und/oder PFA-Leitungen resistent gegen viele chemische Einflüsse bei gleichzeitig hoher mechanischer Beständigkeit. Mögliche Einsatzgebiete sind zum Beispiel in der Chemischen Industrie, im Ofenbau oder in der Nachrichtentechnik.
Kabel für die Kran-/Hebetechnik

Kabel für die Kran-/Hebetechnik

Maßgeschneiderte Kabellösungen für die Kran-/Hebetechnik: Hallenkräne, Hafenkräne, Mobilkräne. Harte Einsatzbedingungen im täglichen Baustellen- oder Verladebetrieb bedeuten starke mechanische und physikalische Beanspruchungen für Kabel im Kranbau und der Hebetechnik. Kabel und Leitungen für diesen Bereich müssen z.B. trommelbar sein und daher flexibel und äußerst stabil zugleich. Wir bieten Ihnen Bauformen und Materialkompositionen, die exakt auf die mechanischen Dauerbelastungen im Hebe- und Verladebetrieb abgestimmt sind. Auch befindet sich die Kabeltechnik für Kräne und Hebeanlagen in permanentem Kontakt mit Schmierstoffen und ist unter Umständen aggressiven Medien ausgesetzt. Kabelummantelungen müssen daher entsprechend robust ausgeführt sein. Das gilt auch in Hinsicht auf Temperatureinflüsse und Witterungsbedingungen. Da Kran- und Hebetechnik in der Regel im Außenbereich stationiert ist, z.B. auf Baustellen oder an Hafenanlagen, sind die hier eingesetzten Kabel und Leitungen ständig wechselnden Witterungsbedingungen unterworfen.
E-DAT modul Cat.6A 8(8) Buchse

E-DAT modul Cat.6A 8(8) Buchse

‧ modulare Anschlusseinheit Cat.6A, RJ45 ‧ Cat.6A Komponentenprüfung nach ISO/IEC 11801, DIN EN 50173-1, ANSI/TIA-568.2-D und IEC 60603-7-51, GHMT zertifiziert ‧ Einhaltung der Klasse EA nach ISO/IEC 11801, DIN EN 50173-1 ‧ getestet: Link bis 500 MHz ‧ montagefreundlicher Anschluss der 2- bis 4-paarigen Datenleitung AWG 26/1 - 22/1 und Litzenleiter mit 7-drähtiger Cu-Litze AWG 26/7 - 22/7 an BTR 8fach IDC-Schneidklemmen ‧ Kennzeichnung der Adernbelegung T568A und T568B ‧ leichtes und schnelles Einlegen der Adernpaare in das E-DAT modul Ladestück ‧ Modulgehäuse aus Zinkdruckguss, veredelt ‧ Montage ohne Spezialwerkzeug ‧ Zugentlastung mit Kabelbinder am Modul ‧ Befestigungsmöglichkeit für Staubschutzklappe ‧ Einbauform: MC Modul ‧ Kabelzuführung 180° ‧ Lieferung in einer 10er Verpackung, einzeln lieferbar
BayEnergy®  N2XH-O  0,6/1 kV  1-2-adrig

BayEnergy® N2XH-O 0,6/1 kV 1-2-adrig

Starkstromkabel mit verbessertem Verhalten im Brandfall, halogenfrei, flammwidrig und raucharm z.B. für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen. Kabel mit verbessertem Verhalten im Brandfall. Im Innen- und Außenbereich, im Freien (vor Sonneneinstrahlung geschützt), jedoch nicht direkt in der Erde, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist, (siehe DIN VDE 0298-1).
BayEnergy®  NAYCWY  0,6/1 kV  4+1-adrig

BayEnergy® NAYCWY 0,6/1 kV 4+1-adrig

Starkstromkabel zur Energieverteilung in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen, wenn ein Schutz gegen Berührungsspannung bei mechanischer Beschädigung erforderlich ist. In Innenräumen und Kabelkanälen, im Freien, im Erdreich für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, wenn ein Schutz gegen Berührungsspannung bei mechanischer Beschädigung erforderlich ist. (Siehe DIN VDE 0298-1). Die EMV+ Konstruktion wird speziell im 4+1 Leitersystem TN-S mit einem getrennten Neutralleiter (N) und querschnittsgleichem Schutzleiter (PE) eingesetzt. Durch den besseren Leitwert im PE-Leiter werden EMV-Störungen optimal reduziert und bieten einen höheren Schutz als bei Kabeln mit reduziertem Außenleiter (4½-Leiter). Die Kabel sind unempfindlich gegen gelegentliche Einwirkungen von Ölen und Kraftstoffen.
BayEnergy®  N2XH-O  0,6/1 kV  3-adrig

BayEnergy® N2XH-O 0,6/1 kV 3-adrig

Starkstromkabel mit verbessertem Verhalten im Brandfall, halogenfrei, flammwidrig und raucharm z.B. für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen. Kabel mit verbessertem Verhalten im Brandfall. Im Innen- und Außenbereich, im Freien (vor Sonneneinstrahlung geschützt), jedoch nicht direkt in der Erde, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist, (siehe DIN VDE 0298-1).
BayEnergy®  N2XH-O  0,6/1 kV   4-5-adrig

BayEnergy® N2XH-O 0,6/1 kV 4-5-adrig

Starkstromkabel mit verbessertem Verhalten im Brandfall, halogenfrei, flammwidrig und raucharm z.B. für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen. Kabel mit verbessertem Verhalten im Brandfall. Im Innen- und Außenbereich, im Freien (vor Sonneneinstrahlung geschützt), jedoch nicht direkt in der Erde, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist, (siehe DIN VDE 0298-1).
BayEnergy®  N2XH-O  0,6/1 kV  vieladrig

BayEnergy® N2XH-O 0,6/1 kV vieladrig

Starkstromkabel mit verbessertem Verhalten im Brandfall, halogenfrei, flammwidrig und raucharm z.B. für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen. Kabel mit verbessertem Verhalten im Brandfall. Im Innen- und Außenbereich, im Freien (vor Sonneneinstrahlung geschützt), jedoch nicht direkt in der Erde, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist, (siehe DIN VDE 0298-1).
3 in 1 Ladekabel mit Beleuchtung REFLECTS-PUHALANI

3 in 1 Ladekabel mit Beleuchtung REFLECTS-PUHALANI

Das Multi-Ladekabel mit 8-Pin-Kabel für Geräte von Apple®, Micro USB und USB-C. Der per Laserdruck veredelte Bereich Ihres Logos wird je nach Modell blau, rot, grün, weiß oder mit Wechsellicht hinterleuchtet und wirkt so besonders apart. Apple® is a registered trademark of Apple Inc. registered in the US and other countries. Kunststoff, Metall, schwarz, schwarz/weiß, silber, LED-Farbe weiß, USB 2.0, USB-Kabel inklusive Artikelnummer: 1336430 Druckbereich: 20 x 19 Zolltarifnummer: 85444290 Gewicht: 26,0 g
3 in 1 Ladekabel mit Beleuchtung REFLECTS-PUHALANI

3 in 1 Ladekabel mit Beleuchtung REFLECTS-PUHALANI

Das Multi-Ladekabel mit 8-Pin-Kabel für Geräte von Apple®, Micro USB und USB-C. Der per Laserdruck veredelte Bereich Ihres Logos wird je nach Modell blau, rot, grün, weiß oder mit Wechsellicht hinterleuchtet und wirkt so besonders apart. Apple® is a registered trademark of Apple Inc. registered in the US and other countries. Kunststoff, Metall, schwarz, schwarz/rot, silber, LED-Farbe rot, USB 2.0, USB Typ C Artikelnummer: 1336429 Druckbereich: 20 x 19 Zolltarifnummer: 85444290 Gewicht: 26,0 g
3 in 1 Ladekabel mit Beleuchtung REFLECTS-PUHALANI

3 in 1 Ladekabel mit Beleuchtung REFLECTS-PUHALANI

Das Multi-Ladekabel mit 8-Pin-Kabel für Geräte von Apple®, Micro USB und USB-C. Der per Laserdruck veredelte Bereich Ihres Logos wird je nach Modell blau, rot, grün, weiß oder mit Wechsellicht hinterleuchtet und wirkt so besonders apart. Apple® is a registered trademark of Apple Inc. registered in the US and other countries. Kunststoff, Metall, schwarz, schwarz/blau, silber, LED-Farbe blau, Polybeutel, USB 2.0, USB Typ C Artikelnummer: 1336426 Druckbereich: 20 x 19 Zolltarifnummer: 85444290 Gewicht: 26,0 g
3 in 1 Ladekabel mit Beleuchtung REFLECTS-PUHALANI

3 in 1 Ladekabel mit Beleuchtung REFLECTS-PUHALANI

Das Multi-Ladekabel mit 8-Pin-Kabel für Geräte von Apple®, Micro USB und USB-C Der per Laserdruck veredelte Bereich Ihres Logos wird je nach Modell blau, rot, grün, weiß oder mit Wechsellicht hinterleuchtet und wirkt so besonders apart. Apple® is a registered trademark of Apple Inc. registered in the US and other countries. Kunststoff, Metall, schwarz, schwarz/grün, silber, LED-Farbe grün, USB 2.0, USB Typ C Artikelnummer: 1336427 Druckbereich: 20 x 19 Zolltarifnummer: 85444290 Gewicht: 26,0 g
BayEnergy®  NYCWY  0,6/1 kV  4+1-adrig

BayEnergy® NYCWY 0,6/1 kV 4+1-adrig

Starkstromkabel zur Energieverteilung in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen, wenn ein Schutz gegen Berührungsspannung bei mechanischer Beschädigung erforderlich ist. Im Innen- und Außenbereich, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen sowie in Ortsnetzen, wenn ein Schutz gegen Berührungsspannung bei mechanischer Beschädigung erforderlich ist (siehe DIN VDE 0298-1). Die EMV+ Konstruktion wird speziell im 4+1 Leitersystem TN-S mit einem getrennten Neutralleiter (N) und querschnittsgleichem Schutzleiter (PE) eingesetzt. Durch den besseren Leitwert im PE-Leiter werden EMV-Störungen optimal reduziert und bieten einen höheren Schutz als bei Kabeln mit reduziertem Außenleiter (4½-Leiter). Die Kabel sind unempfindlich gegen gelegentliche Einwirkungen von Ölen und Kraftstoffen.
EtherCAT® Bridge (ECX-EC)

EtherCAT® Bridge (ECX-EC)

"Bridging" von zwei EtherCAT-Slave-Segmenten - Einbindung von zwei EtherCAT-Slave-Geräten - Prozessdatenaustasch zwischen zwei EtherCAT-Netzwerken - Zeitsynchronisation (DC) zwischen den EtherCAT-Mastern - Unterstützung von DC mit Redundanz EtherCAT-Implementierung - Ethernet-Physik gemäß IEEE 802.3 - Konfiguration über CoE - Firmware-Update über FoE - EoE Support (Switch-Port) EtherCAT Prozessabbild vielfältig konfigurierbar - Konfiguration über typische Netzwerk-Konfigurations-Tools (z.B. esd Workbench, TwinCAT®) - Bis zu 1024 Bytes in jeder Richtung - Layout über Variablen wählbar, z.B. 'UDINT'
Vario – Kabelmanagementsystem

Vario – Kabelmanagementsystem

Artikelnummer: 00030 Kategorie: Kabelmanagementsystem, Kabelhalter für Elektroauto aus rostfreiem Stahl zur einfachen Wandmontage. Für die praktische Aufbewahrung von Elektrofahrzeug-Ladekabeln. Kabelhalterung zur Wandmontage für Typ2 Ladekabel aus Edelstahl 1.4301 Lieferumfang: Kabelhalterung, 4 Schrauben und 4 Dübel Abmessungen: 150 mm x 152mm x 429mm x 3mm Matte Oberfläche